Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Cardiovasc Intervent Radiol ; 46(12): 1666-1673, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37973663

RESUMO

PURPOSE: To describe a novel technique of transvenous radiofrequency catheter ablation of an aldosterone-producing adenoma (APA) of the left adrenal gland using the GOS System (Japan Lifeline, Tokyo, Japan). Using the GOS system, a flexible radiofrequency tip catheter can be inserted into the adrenal central and tributary veins, the drainers for functional tumors. MATERIALS AND METHODS: An APA at the left adrenal gland, which was diagnosed by segmental adrenal venous sampling following administration of 0.25 mg cosyntropin, was ablated using the GOS catheter inserted into adrenal tributary veins via a right femoral vein 7-Fr sheath. The effect of radiofrequency ablation on APA was assessed using the international consensus on surgical outcomes for unilateral primary aldosteronism (PA). RESULTS: No device-related complications were observed. The patient was deeply sedated under blood pressure and heart rate control with continuous administration of ß-blockers. Then, the tumor and surrounding adrenal gland were cauterized at 7000 J two times each in sequence. The output time was 7-11 min for each ablation and 80 min in total. For blood pressure and pulse rate control, esmolol hydrochloride and phentolamine mesylate were used. The contrast enhancement of APA disappeared on dynamic CT immediately after the procedure. PA was biochemically cured until 12 months after the procedure. CONCLUSION: Using the radiofrequency device with the GOS catheter and system is a method for cauterizing adrenal tumors from blood vessels. This approach resulted in a marked reduction in aldosterone concentrations and a complete biochemical cure of PA over the observation period.


Assuntos
Neoplasias das Glândulas Suprarrenais , Ablação por Cateter , Hiperaldosteronismo , Humanos , Aldosterona , Glândulas Suprarrenais/diagnóstico por imagem , Glândulas Suprarrenais/cirurgia , Glândulas Suprarrenais/irrigação sanguínea , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/cirurgia , Cateteres/efeitos adversos , Ablação por Cateter/métodos , Hiperaldosteronismo/etiologia , Hiperaldosteronismo/cirurgia , Hiperaldosteronismo/diagnóstico
2.
Materials (Basel) ; 16(6)2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36984256

RESUMO

Polyethylene terephthalate (PET) is known to be highly inert, and this makes it difficult to be metallized. In addition, Pt electroless plating is rarely reported in the metallization of polymers. In this study, the metallization of biocompatible Pt metal is realized by supercritical CO2 (sc-CO2)-assisted electroless plating. The catalyst precursor used in the sc-CO2 catalyzation step is an organometallic compound, palladium (II) acetylacetonate (Pd(acac)2). The electrical resistance is evaluated, and a tape adhesion test is utilized to demonstrate intactness of the Pt layer on the PET film. The electrical resistance of the Pt/PET with 60 min of the Pt deposition time remains at a low level of 1.09 Ω after the adhesion test, revealing positive effects of the sc-CO2 catalyzation step. A tensile test is conducted to evaluate the mechanical strength of the Pt/PET. In-situ electrical resistances of the specimen are monitored during the tensile test. The fracture strength is determined from the stress value when the short circuit occurred. The fracture strength is 33.9 MPa for a specimen with 30 min of the Pt deposition time. As the Pt deposition time increases to 45 min and 60 min, the fracture strengths reach 52.3 MPa and 65.9 MPa, respectively. The promoted fracture strength and the decent electrical conductivity demonstrate the advantages toward biomedical devices.

3.
Materials (Basel) ; 16(3)2023 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-36770173

RESUMO

In vitro studies on adherent cells require a process of passage to dissociate the cells from the culture substrate using enzymes or other chemical agents to maintain cellular activity. However, these proteolytic enzymes have a negative influence on the viability and phenotype of cells. The mesenchymal stem cell (MSC)-like cell line, C3H10T1/2, adhered, migrated, and proliferated to the same extent on newly designed microporous titanium (Ti) membrane and conventional culture dish, and spontaneous transfer to another substrate without enzymatic or chemical dissociation was achieved. The present study pierced a 10 µm-thick pure Ti sheet with 25 µm square holes at 75 µm intervals to create a dense porous structure with biomimetic topography. The pathway of machined holes allowed the cells to access both sides of the membrane frequently. In a culture with Ti membranes stacked above- and below-seeded cells, cell migration between the neighboring membranes was confirmed using the through-holes of the membrane and contact between the membranes as migration routes. Furthermore, the cells on each membrane migrated onto the conventional culture vessel. Therefore, a cell culture system with enzyme-free passaging was developed.

4.
Materials (Basel) ; 14(22)2021 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-34832206

RESUMO

Oral dysfunction due to peri-implantitis and shortened life of implants has become a major concern. Self-care and removal of oral biofilms by professional mechanical tooth cleaning (PMTC) are indispensable for its prevention. However, if the surface roughness of the implant is increased, it may result in the adhesion of biofilm in the oral cavity. Therefore, the PMTC method can serve for long-term implant management. Calcium carbonate (CaCO3) has been used as a cleaning method for implant surfaces; however, there is concern that the implant surface roughness could increase due to particle collision. Therefore, in this study, to establish a blasting cleaning method that does not adversely affect the implant surface, a new blasting cleaning method using agar particles was devised and its practical application examined. When the simulated stains were blasted with white alumina (WA) abrasive grains and CaCO3 particles, the simulated stains were almost removed, the surface roughness changed to a satin-finished surface-which was thought to be due to fine scratches-and the surface roughness increased. Most of the simulated stains were removed on the surface of the sample blasted with glycine particles and agar particles. Conversely, the gloss of the sample surface was maintained after cleaning, and the increase in surface roughness was slight.

5.
Materials (Basel) ; 14(12)2021 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-34204390

RESUMO

Acute-type lateral ridge defects (25 mm × 6 mm × 5 mm) were bilaterally created in the mandibles of four dogs (two defects per animal). The defects were reconstructed with particulate autologous bone and covered with a microperforated titanium membrane (Ti-honeycomb membrane, TiHM) or an existing conventional titanium mesh as control. The samples were dissected after 16 weeks postoperatively and processed for radiographic, histologic, and histomorphometric analyses. Regenerated tissue and bone volume were significantly larger in the TiHM group than in the control group (p = 0.05; p = 0.049). In contrast, bone mineral density was similar between the two groups. Histomorphometric analysis revealed that the regenerated bone area and calcific osseous area were larger in the TiHM group than in the control group; however, the differences were not significant. The efficacy of TiHM was generally satisfactory with the potential to become a standard tool for the GBR procedure; however, early membrane exposure will be a major problem to overcome.

6.
Materials (Basel) ; 13(22)2020 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-33266468

RESUMO

The surface topography of Titanium (Ti) combined toughness and biocompatibility affects the attachment and migration of cells. Limited information of morphological characteristics, formed by precise machining in micron order, is currently available on the Ti that could promote osteoconduction. In the present study, a pure Ti membrane was pierced with precise 25 µm square holes at 75 µm intervals and appear burrs at the edge of aperture. We defined the surface without burrs as the "Head side" and that with burrs as the "Tail side". The effects of the machining microtopography on the proliferation and differentiation of the preosteoblasts (MC3T3-E1 cells) were investigated. The cells were more likely to migrate to, and accumulate in, the aperture of holes on the head side, but grew uniformly regardless of holes on the tail side. The topography on the both surfaces increased osteopontin gene expression levels. Osteocalcin expression levels were higher on the head side than one on the blank scaffold and tail side (p < 0.05). The osteocalcin protein expression levels were higher on the tail side than on the head side after 21 days of cultivation, and were comparable to the proportion of the calcified area (p < 0.05). These results demonstrate the capacity of a novel microporous Ti membrane fabricated using a precise mechanical punching process to promote cell proliferation and activity.

7.
Int J Oral Maxillofac Implants ; 34(5): 1132-1142, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31528864

RESUMO

PURPOSE: This study evaluated the efficacy of newly designed, laser-perforated pure titanium membranes for guided bone regeneration using beta-tricalcium phosphate (ß-TCP), and compared them with the existing membrane. MATERIALS AND METHODS: Bilateral acute lateral ridge defects were created in the mandibles of 12 dogs (four defects per animal), which were then randomly divided into two groups (six dogs each). The twenty-four bone defects in each group were then further divided into five groups. The groups were as follows: (1) F001M0, a prototype membrane without a frame plus ß-TCP (n = 5); (2) F001M1, a prototype membrane with a frame plus ß-TCP (n = 5); (3) FBS, an existing control membrane plus ß-TCP (n = 5); (4) control 1, ß-TCP without membrane and with covering flap only (n = 5); and (5) control 2, no treatment (no ß-TCP and no membrane) (n = 4). In all groups where ß-TCP was used, it was mixed with peripheral blood. The animals were necropsied at 6 or 12 weeks postoperatively (six dogs each), and samples were collected and processed for radiographic, histologic, and histomorphometric analyses. RESULTS: Among the three membrane groups, regenerated tissue and bone volume was greatest in the F001M1 group at both 6 and 12 weeks postoperatively, although differences among groups were not statistically significant. Bone mineral density was similar among the membrane groups. Histologic analysis revealed that immature fibroblasts were present on the laser-perforated portion at 6 weeks, which induced vascularization. In addition, more calcified bone was replaced beneath the prototypes than beneath the FBS membrane at 12 weeks. Histomorphometric analyses revealed that the calcific osseous areas at 12 weeks after surgery were significantly greater in the F001M1 and F001M0 groups than in the FBS group (P = .021, P = .032). Furthermore, the fibrous tissue areas beneath the membrane at 12 weeks postoperatively were significantly smaller in the prototype groups than in the FBS group (P = .02, P = .02). CONCLUSION: The efficacies of both prototype membranes were not inferior to that of the FBS membrane, indicating that they may facilitate bone regeneration and maturation when ß-TCP mixed with autologous blood is employed.


Assuntos
Regeneração Óssea , Substitutos Ósseos , Titânio , Animais , Fosfatos de Cálcio , Cães , Mandíbula , Membranas
8.
Dent Mater J ; 38(6): 963-969, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31434831

RESUMO

The aim of this study was to investigate the effects of artificial saliva on permeability measured using a highly sensitive digital flow meter of dentin discs treated with a phosphate containing desensitizer compound (Teethmate desensitizer; TD). Four random groups (n=10) were treated either with TD or distilled water (DW), then stored in artificial saliva (AS) or DW for 1 day, 1 week and 1 month. Flow rates under 2 kPa pressure were calculated as percentage reduction (PR%) from the baseline. The PR% of TD/AS group was significantly lower after 1 day and 1 week, but the PR%s of 1 month groups among TD/AS, TD/DW and DW/AS were not significantly different. The SEM photograph of TD/AS group displayed that the dentin surface was densely covered with mineral deposits. Ca and phosphate ions from the artificial saliva could penetrate into the tubules and precipitate as hydroxyapatite, resulting in the reduction in permeability.


Assuntos
Permeabilidade da Dentina , Sensibilidade da Dentina , Dentina , Humanos , Microscopia Eletrônica de Varredura , Permeabilidade , Saliva Artificial
9.
Int J Oral Maxillofac Implants ; 34(2): 411-422, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30883620

RESUMO

PURPOSE: This study aimed to evaluate the safety and efficacy of newly designed, laser-perforated pure titanium membranes for guided bone regeneration and to compare them with an existing product, the FRIOS BoneShield (FBS). MATERIALS AND METHODS: Acute-type lateral ridge defects were bilaterally created in the mandibles of 13 dogs (two defects per animal). The defects were randomly divided into three groups and were reconstructed with particulate autologous bone (PAB) in combination with three different titanium membranes: (1) F001M0 (prototype without a frame), (2) F001M1 (prototype with a frame), and (3) FBS as a standard membrane. All animals were observed periodically and sacrificed 26 or 27 weeks postoperatively. At 26 weeks, approximately half of the dogs in each group underwent membrane removal to examine the postoperative condition of the titanium membranes. The samples were dissected and processed for radiographic, histologic, and histomorphometric analyses. RESULTS: Membrane exposure was not found in the F001M0 or F001M1 groups, and their membranes were removed easily without adhesion to the surrounding tissue. Regenerated bone tissue volume was largest in the F001M1 group, followed by the F001M0 and FBS groups. A significant difference was observed only between the F001M1 and FBS groups (P = .047). In contrast, bone mineral density was similar among the three groups. Histologically, a layer of fibrous tissue was present underneath the titanium membrane, overlying the regenerated cortical bone in all the groups. Notably, the tissue was highly vascular in the F001M1 and F001M0 groups compared with the FBS group. In addition, there was little difference in the semiquantitative soft tissue evaluation and histologic findings of bone regeneration among the three groups. The histomorphometric analysis revealed that the regenerated bone area was larger in the F001M1 and F001M0 groups than in the FBS group, and a significant difference was observed only between the F001M1 and FBS groups (P = .045). Calcific osseous area was similar among the three groups. CONCLUSION: The safety and efficacy of both F001M0 and F001M1 were equivalent to or greater than those of FBS, thereby indicating their potential for future clinical applications.


Assuntos
Regeneração Óssea , Regeneração Tecidual Guiada Periodontal/métodos , Mandíbula/cirurgia , Membranas Artificiais , Titânio , Animais , Cães , Modelos Animais , Politetrafluoretileno
10.
J Appl Oral Sci ; 25(1): 34-41, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28198974

RESUMO

OBJECTIVE: The aim of this in vitro study was to investigate the effect of two desensitizing agents and water on hydraulic conductance in human dentin. MATERIAL AND METHODS: GLUMA Desensitizer PowerGel (GLU) contains glutaraldehyde (GA) and 2-hydroxyethyl methacrylate (HEMA), and Teethmate Desensitizer (TD) is a powder comprising tetracalcium phosphate (TTCP) and dicalcium phosphate anhydrous (DCPA) that is mixed with water. Deionized water was used as a negative control (CTR). Thirty discs with a thickness of 1.2 mm were cut from the coronal dentin of the third molars and cleaned with 0.5 M EDTA (pH 7.4). After being mounted in a split-chamber device, the discs were pressurized with water at 1 kPa and 3 kPa in order to measure flow rates with a highly sensitive micro-flow sensor and to calculate hydraulic conductance as a baseline value (BL). Following the application of GLU, TD, and CTR (n=10), hydraulic conductance was remeasured with intermittent storage in water after 15 min, 1 d, 1 w, and 1 m. Reduction in permeability (PR%) was calculated from hydraulic conductance. Data were statistically analyzed using nonparametric methods (α<0.05). Representative discs were inspected by SEM. RESULTS: PR% for GLU and TD were 30-50% 15 min and 1 m after their application. Post hoc tests indicated that PR% of CTR was significantly greater than those of GLU and TD at all time points tested. The PR% of GLU and TD were not significantly different. SEM examinations showed noncollapsed collagen meshes at the tubular entrances after GLU, and crystalline precipitates occluding the tubular orifices after TD, whereas CTR specimens showed typical patterns of etched dentin. CONCLUSIONS: The present study on hydraulic conductance in dentin discs treated with two chemically different desensitizing agents and water as a control demonstrated that both products may be characterized as effective.


Assuntos
Fosfatos de Cálcio/química , Dessensibilizantes Dentinários/química , Permeabilidade da Dentina/efeitos dos fármacos , Dentina/efeitos dos fármacos , Glutaral/química , Metacrilatos/química , Ácido Edético/química , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Estatísticas não Paramétricas , Propriedades de Superfície , Fatores de Tempo , Água/química
11.
J. appl. oral sci ; 25(1): 34-41, Jan.-Feb. 2017. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-841160

RESUMO

Abstract Objective The aim of this in vitro study was to investigate the effect of two desensitizing agents and water on hydraulic conductance in human dentin. Material and Methods GLUMA Desensitizer PowerGel (GLU) contains glutaraldehyde (GA) and 2-hydroxyethyl methacrylate (HEMA), and Teethmate Desensitizer (TD) is a powder comprising tetracalcium phosphate (TTCP) and dicalcium phosphate anhydrous (DCPA) that is mixed with water. Deionized water was used as a negative control (CTR). Thirty discs with a thickness of 1.2 mm were cut from the coronal dentin of the third molars and cleaned with 0.5 M EDTA (pH 7.4). After being mounted in a split-chamber device, the discs were pressurized with water at 1 kPa and 3 kPa in order to measure flow rates with a highly sensitive micro-flow sensor and to calculate hydraulic conductance as a baseline value (BL). Following the application of GLU, TD, and CTR (n=10), hydraulic conductance was remeasured with intermittent storage in water after 15 min, 1 d, 1 w, and 1 m. Reduction in permeability (PR%) was calculated from hydraulic conductance. Data were statistically analyzed using nonparametric methods (α<0.05). Representative discs were inspected by SEM. Results PR% for GLU and TD were 30-50% 15 min and 1 m after their application. Post hoc tests indicated that PR% of CTR was significantly greater than those of GLU and TD at all time points tested. The PR% of GLU and TD were not significantly different. SEM examinations showed noncollapsed collagen meshes at the tubular entrances after GLU, and crystalline precipitates occluding the tubular orifices after TD, whereas CTR specimens showed typical patterns of etched dentin. Conclusions The present study on hydraulic conductance in dentin discs treated with two chemically different desensitizing agents and water as a control demonstrated that both products may be characterized as effective.


Assuntos
Humanos , Fosfatos de Cálcio/química , Glutaral/química , Dentina/efeitos dos fármacos , Permeabilidade da Dentina/efeitos dos fármacos , Dessensibilizantes Dentinários/química , Metacrilatos/química , Propriedades de Superfície , Fatores de Tempo , Teste de Materiais , Água/química , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Ácido Edético/química , Estatísticas não Paramétricas
12.
Arch Oral Biol ; 60(1): 193-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25455134

RESUMO

OBJECTIVE: To evaluate the flow dynamics of dentine fluid using a chemiluminescence method in vitro. MATERIALS AND METHODS: Horizontally sliced coronal dentine specimens with thicknesses of 1.4, 1.6, 1.8, and 2.0mm (n=10 each) were prepared from extracted human third molars. After cleaning with EDTA, a mounted specimen was clamped between 2 acrylic chambers attached to both the occlusal and pulpal sides. The occlusal chamber, which was closed with a glass coverslip, was filled with a chemiluminescent solution (0.02% luminol and 1% sodium hydroxide in water). A trigger solution of 1% hydrogen peroxide and 1% potassium ferricyanide was injected into the pulpal chamber at a constant pressure of 2.5 kPa, and allowed to immediately flow into the patent dentinal tubules. Four consecutive measurements (T1-T4) were performed on each sample by recording the emission of chemiluminescence with a photodetector. The relationship between the crossing time of the liquid through the slice and dentine thickness was examined. RESULTS: An apparent time delay was detected between the starting points of the trigger solution run and photochemical emission at T1. Dt (Dt, s) values of each thickness group were 13.6 ± 4.25 for 1.4mm, 18.1 ± 2.38 for 1.6mm, 28.0 ± 2.46 for 1.8mm, and 39.2 ± 8.61 for 2.0mm, respectively. Dt significantly decreased as dentine became thinner towards the pulp chamber (P<0.001). CONCLUSIONS: The velocity of fluid flow increased both with increasing dentine depth or reduction of remaining dentine thickness.


Assuntos
Permeabilidade da Dentina/fisiologia , Dentina/fisiologia , Reologia/instrumentação , Líquido Dentinal/fisiologia , Humanos , Técnicas In Vitro , Medições Luminescentes
13.
Am J Dent ; 27(3): 139-44, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25208361

RESUMO

PURPOSE: To evaluate the in vitro and in vivo effects of three treatment regimens on dentin permeability and reduction of dentin hypersensitivity (DH). METHODS: The desensitization treatments were: Gluma Desensitizer PowerGel (GLU), MS Coat One (MSC), and dentin burnishing with fiber-resin burs (STB). A split-chamber device was used to determine the permeability of dentin slices cut from human molars in vitro. Fluid flow through dentin was recorded with a photochemical method after EDTA cleaning, albumin soaking and desensitization treatment (n = 10). 61 study participants with three severely hypersensitive teeth each were enrolled. Sensitivity was determined with an air stimulus before, immediately after treatment, and after 1, 3 and 6 months, using a verbal rating scale. RESULTS: From the 61 study participants enrolled, 52 completed the trial. Permeability at baseline and after albumin soaking was not significantly different. All treatments produced reduced fluid flow through dentin (P > 0.05). All treatments reduced DH significantly (no or moderate sensitivity). Statistical results revealed significant differences among the treatments (P = 0.03). Mann-Whitney comparisons showed GLU, STB < MSC.


Assuntos
Dessensibilizantes Dentinários/uso terapêutico , Permeabilidade da Dentina/efeitos dos fármacos , Sensibilidade da Dentina/tratamento farmacológico , Adulto , Albuminas/farmacologia , Quelantes/farmacologia , Profilaxia Dentária/instrumentação , Dentina/efeitos dos fármacos , Líquido Dentinal/efeitos dos fármacos , Ácido Edético/farmacologia , Resinas Epóxi/química , Feminino , Seguimentos , Vidro/química , Glutaral/uso terapêutico , Humanos , Masculino , Metacrilatos/uso terapêutico , Pessoa de Meia-Idade , Ácido Oxálico/uso terapêutico , Percepção da Dor/efeitos dos fármacos , Polimetil Metacrilato/uso terapêutico , Poliestirenos/uso terapêutico , Zircônio/química
14.
Biomed Res Int ; 2014: 102648, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25165689

RESUMO

Human periodontal ligament (PDL) cells obtained from extracted teeth are a potential cell source for tissue engineering. We previously reported that poly(2-methoxyethyl acrylate) (PMEA) is highly biocompatible with human blood cells. In this study, we investigated the adhesion, morphology, and proliferation of PDL cells on PMEA and other types of polymers to design an appropriate scaffold for tissue engineering. PDL cells adhered and proliferated on all investigated polymer surfaces except for poly(2-hydroxyethyl methacrylate) and poly[(2-methacryloyloxyethyl phosphorylcholine)-co-(n-butyl methacrylate)]. The initial adhesion of the PDL cells on PMEA was comparable with that on polyethylene terephthalate (PET). In addition, the PDL cells on PMEA spread well and exhibited proliferation behavior similar to that observed on PET. In contrast, platelets hardly adhered to PMEA. PMEA is therefore expected to be an excellent scaffold for tissue engineering and for culturing tissue-derived cells in a blood-rich environment.


Assuntos
Acrilatos/uso terapêutico , Materiais Biocompatíveis/uso terapêutico , Proliferação de Células/efeitos dos fármacos , Polímeros/uso terapêutico , Engenharia Tecidual , Acrilatos/química , Adesão Celular/efeitos dos fármacos , Humanos , Ligamento Periodontal/efeitos dos fármacos , Polietilenoglicóis/química , Polietilenoglicóis/uso terapêutico , Polietilenotereftalatos , Polímeros/química , Propriedades de Superfície , Tecidos Suporte/química
15.
Eur J Oral Sci ; 121(5): 477-81, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24028597

RESUMO

The aim of this clinical trial was to compare tooth sensitivity during and after bleaching with hydrogen peroxide gel following application of GLUMA Desensitizer PowerGel or placebo. Forty-six subjects with sound maxillary incisors and canines were enrolled. Tooth shades were determined by comparison with a Vitapan Classic Shade guide. GLUMA Desensitizer PowerGel and placebo were randomly applied to the labial surfaces of the left or right anterior teeth for 1 min, which were then rinsed and dried. Then, Opalescence Boost PF 40% gel was applied onto labial enamel for 15 min. Sensitivity scores [recorded on a 10-point visual-analog scale (VAS)] were determined before, at 5, 10, and 15 min during, and 1, 24, 48 h and 1 wk after, the bleaching treatment. Shades were determined postbleaching and after 1 wk. Prebleaching application of GLUMA Desensitizer PowerGel significantly reduced tooth sensitivity during and after bleaching when compared with treatment with placebo. The whitening effects immediately and 1 wk after bleaching were significant when compared with the prebleaching shades. In conclusion, tooth pretreatment with GLUMA Desensitizer PowerGel for 1 min prior to 15 min of in-office bleaching with 40% hydrogen peroxide gel was highly effective in reducing tooth sensitivity during and after bleaching.


Assuntos
Esmalte Dentário/efeitos dos fármacos , Dessensibilizantes Dentinários/administração & dosagem , Sensibilidade da Dentina/terapia , Peróxido de Hidrogênio/administração & dosagem , Clareadores Dentários/administração & dosagem , Clareamento Dental/métodos , Adulto , Análise de Variância , Feminino , Humanos , Masculino , Medição da Dor , Resultado do Tratamento
16.
Eur J Oral Sci ; 120(6): 558-62, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23167474

RESUMO

A powder jet deposition (PJD) process can be used to create a thick hydroxyapatite (HA) film on the surface of a human tooth. This study aimed to investigate in vitro the ability of an HA film, applied using PJD, to diminish dentin permeability. Discs of human coronal dentin were cut perpendicular to the tooth axis and the smear layer was removed by EDTA treatment. The HA film was created by accelerating HA particles, calcinated at 1200°C, onto the dentin discs at room temperature and atmospheric pressure. The surfaces and cross-sections of the HA PJD-treated samples were observed using scanning electron microscopy. Their permeability was indirectly recorded with a split-chamber device utilizing a chemiluminescence technique. MS-coat, a commercial dentin-desensitizing agent, was also evaluated for its effect on reducing liquid flow through the dentin. The scanning electron microscopy images showed that the HA particles were successfully deposited onto the dentin and solidly into the dentin tubules. The permeability of dentin after application of the HA films was significantly lower than that following application of MS-coat. This study showed the potential clinical application of PJD techniques in desensitizing dentin hypersensitivity.


Assuntos
Dessensibilizantes Dentinários/uso terapêutico , Permeabilidade da Dentina/efeitos dos fármacos , Sensibilidade da Dentina/tratamento farmacológico , Dentina/efeitos dos fármacos , Durapatita/uso terapêutico , Teste de Materiais/instrumentação , Dessensibilizantes Dentinários/farmacologia , Durapatita/farmacologia , Humanos , Medições Luminescentes/instrumentação , Teste de Materiais/métodos , Microscopia Eletrônica de Varredura , Propriedades de Superfície
17.
J Appl Oral Sci ; 19(2): 147-53, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21552716

RESUMO

OBJECTIVES: To assess and to compare the effects of Gluma® Desensitizer (GDL) with an experimental glutaraldehyde and HEMA containing fumed silica dispersion (GDG) on dentin permeability using a chemiluminous tracer penetration test. MATERIAL AND METHODS: Twenty disc-shaped dentin specimens were dissected from extracted human third molars. The dentin specimens were mounted in a split chamber device for determination of permeability under liquid pressure using a photochemical method. Ten specimens were randomly selected and allocated to the evaluation groups Gluma® Desensitizer as aqueous solution and glutaraldehyde/HEMA as fumed silica dispersion, respectively. Dentin disc permeability was determined at two pressure levels after removal of smear with EDTA, after albumin soaking, and after application of the desensitizing agents. Two desensitizer-treated and rinsed specimens of each group were examined by scanning electron microscopy (SEM) for surface remnants. RESULTS: Comparatively large standard deviations of the mean EDTA reference and albumin soaked samples permeability values reflected the differences of the dentin substrates. The mean chemiluminescence values of specimen treated with GDL and GDG, respectively, were significantly reduced after topical application of the desensitizing agents on albumin-soaked dentin. The effects of GDL and GDG on permeability were not significantly different. Treated specimens showed no surface remnants after rinsing. CONCLUSIONS: The experimental desensitizer gel formulation reduced dentin permeability as effectively as the original Gluma® Desensitizer solution.


Assuntos
Dessensibilizantes Dentinários/farmacologia , Permeabilidade da Dentina/efeitos dos fármacos , Dentina/efeitos dos fármacos , Glutaral/farmacologia , Metacrilatos/farmacologia , Dessensibilizantes Dentinários/química , Sensibilidade da Dentina/tratamento farmacológico , Glutaral/química , Humanos , Técnicas In Vitro , Luminescência , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Dióxido de Silício/química , Propriedades de Superfície/efeitos dos fármacos
18.
J. appl. oral sci ; 19(2): 147-153, May-Apr. 2011. ilus
Artigo em Inglês | LILACS | ID: lil-586035

RESUMO

OBJECTIVES: To assess and to compare the effects of Gluma® Desensitizer (GDL) with an experimental glutaraldehyde and HEMA containing fumed silica dispersion (GDG) on dentin permeability using a chemiluminous tracer penetration test. MATERIAL AND METHODS: Twenty disc-shaped dentin specimens were dissected from extracted human third molars. The dentin specimens were mounted in a split chamber device for determination of permeability under liquid pressure using a photochemical method. Ten specimens were randomly selected and allocated to the evaluation groups Gluma® Desensitizer as aqueous solution and glutaraldehyde/HEMA as fumed silica dispersion, respectively. Dentin disc permeability was determined at two pressure levels after removal of smear with EDTA, after albumin soaking, and after application of the desensitizing agents. Two desensitizer-treated and rinsed specimens of each group were examined by scanning electron microscopy (SEM) for surface remnants. RESULTS: Comparatively large standard deviations of the mean EDTA reference and albumin soaked samples permeability values refected the differences of the dentin substrates. The mean chemiluminescence values of specimen treated with GDL and GDG, respectively, were signifcantly reduced after topical application of the desensitizing agents on albumin-soaked dentin. The effects of GDL and GDG on permeability were not signifcantly different. Treated specimens showed no surface remnants after rinsing. CONCLUSIONS: The experimental desensitizer gel formulation reduced dentin permeability as effectively as the original Gluma® Desensitizer solution.


Assuntos
Humanos , Dessensibilizantes Dentinários/farmacologia , Permeabilidade da Dentina/efeitos dos fármacos , Dentina/efeitos dos fármacos , Glutaral/farmacologia , Técnicas In Vitro , Metacrilatos/farmacologia , Dessensibilizantes Dentinários/química , Sensibilidade da Dentina/tratamento farmacológico , Glutaral/química , Luminescência , Teste de Materiais , Microscopia Eletrônica de Varredura , Metacrilatos/química , Distribuição Aleatória , Dióxido de Silício/química , Propriedades de Superfície/efeitos dos fármacos
19.
Am J Dent ; 22(3): 143-6, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19650593

RESUMO

PURPOSE: To investigate the in vitro efficacy of two dentin desensitizing products at reducing liquid permeability through human dentin discs. The tested hypothesis was that the products, in spite of different chemical mechanisms were not different at reducing or eliminating flow through dentin discs. METHODS: Dentin slices (1 mm thick) were prepared from 16 extracted human third molars and their permeability was indirectly recorded in a split chamber model, using a chemiluminescence technique, after EDTA treatment (control), after soaking with albumin, and after desensitizer application. Two products were studied: MS Coat, a self-curing resin-containing oxalate product, and Gluma Desensitizer, a glutaraldehyde/HEMA-based agent without initiator. The dentin slices were mounted between an upper chamber, filled with an aqueous solution of 1% potassium ferricyanide and 0.3% hydrogen peroxide, and a lower chamber filled with 1% sodium hydroxide solution and 0.02% luminol. The upper solution was pressurized, and upon contact with the luminol solution a photochemical signal was generated and recorded as a measure of permeability throughout two consecutive pressurizing cycles at 2.5 and 13 kPa (26 and 133 cm H2O), respectively. RESULTS: The permeability of the control and albumin-soaked samples was similarly high. After application of the desensitizing agents, dentin permeability was reduced to virtually zero at both pressure levels (P < 0.001).


Assuntos
Permeabilidade da Dentina/efeitos dos fármacos , Sensibilidade da Dentina/tratamento farmacológico , Glutaral/farmacologia , Metacrilatos/farmacologia , Oxalatos/farmacologia , Líquido Dentinal/fisiologia , Humanos , Luminescência , Teste de Materiais
20.
J Dent ; 37(6): 432-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19250732

RESUMO

OBJECTIVE: To investigate and compare bonding and dentin sealing efficacy of a marketed all-in-one and an experimental model adhesive with minimum effective amounts of acidic monomer and water. MATERIALS AND METHODS: Composition of model adhesive (NAD) in mass%: UDMA (45), 4-META (20), H2O (7.5), and acetone (27.5). For characterization of a reasonable NAD application procedure shear bond strengths (SBS, n=8) were determined on human enamel and dentin. Clearfil S3 Bond (TSB; Kuraray) served as reference. SBSs were evaluated after 10 min, 1 and 7 days, and 1 month, marginal adaptation (n=8) was assessed in cylindrical butt-joint dentin cavities. Diffusive and convective water fluxes through 1mm thick adhesive-coated dentin disks (n=6) were qualitatively and quantitatively analyzed. RESULTS: SBSs proved that application of NAD in one coat with 20s agitated dwell time was > or =20 MPa, enamel SBSs (24h) were 25 MPa, p>0.05. Dentin SBSs for TSB and NAD were not different (p>0.05) at the four stages (means: 18.9, 23.5, 25.4, and 23.6 MPa). Five and seven of the eight bonded restorations with TSB and NAD were gap-free (p>0.05). Dentin disks treated with EDTA from both sides or one side only were highly permeable for liquid, whereas adhesive-coated dentin disks showed no permeability at 0 and 2.5 kPa water pressure. CONCLUSIONS: Within the limitations of this study the model adhesive tested represents a promising basic composition for all-in-one adhesives, eliminating common problems encountered with single step adhesives such as phase separation and permeability.


Assuntos
Colagem Dentária , Adesivos Dentinários/química , Acetona/química , Adolescente , Adulto , Quelantes/química , Química Farmacêutica , Esmalte Dentário/ultraestrutura , Adaptação Marginal Dentária , Dentina/ultraestrutura , Permeabilidade da Dentina , Ácido Edético/química , Feminino , Humanos , Pressão Hidrostática , Substâncias Luminescentes , Luminol , Masculino , Teste de Materiais , Metacrilatos/química , Poliuretanos/química , Cimentos de Resina/química , Resistência ao Cisalhamento , Solventes/química , Estresse Mecânico , Fatores de Tempo , Água/química , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...